Volume 6, Issue 3 (July 2022)                   AOH 2022, 6(3): 1296-1308 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

hokmabadi R, karimi A. Application of Hazard and Operability Analysis (HAZOP) Method for Risk Analysis in CGS Station. AOH 2022; 6 (3) :1296-1308
URL: http://aoh.ssu.ac.ir/article-1-289-en.html
1- Department of Occupational Health Engineering, Faculty of Health, Tehran University of Medical Sciences, Tehran, Iran. Faculty member of Health School, North Khorasan University of Medical Sciences, Bojnurd, Iran
2- Department of Occupational Health Engineering, Faculty of Health, Tehran University of Medical Sciences, Tehran, Iran , alikarimi57@gmail.com
Abstract:   (553 Views)
Background: The hazard and operability study (HAZOP) method is a risk assessment method based on engineering systems used for qualitative analysis or quantitative evaluation. It is mainly used to discover potential hazards and operational difficulties in the design and qualitative stages of chemical systems. The study aims to apply the HAZOP method in process and safety operations at gas depressurization station. Methods: This descriptive study was performed at CGS station. The station was divided into four principal nodes including: filter, heater, regulator, and odorize part. Required information for HAZOP worksheets were gathered by operational procedures, daily reports and interviews with engineers and operators working at the station. To determine the severity of consequences and probability of occurrence of scenarios that were predicted based on the risk matrix, the amount of risk was specified and the necessary suggestions were made in this regard. Results: According to this study, the operational indicators in the pressure reducing station process included pressure, flow, level and temperature. 22 main deviations and 50 causes of failures were identified. 5 deviations (23%) were in the low risk range (green area) and 17 (77%) were in the medium risk range (yellow area). Conclusions:  Causes and effects of deviations in operational parameters at four nodes in gas depressurization station were identified by HAZOP. Preventive actions were emphasized, such as consistent inspection of pipelines, preventive and timely maintenance and preparing a well-scheduled plan for inspecting the equipment in terms of corrosion, inspection, and design revision.
Full-Text [PDF 4348 kb]   (181 Downloads)    
Type of Study: Applicable | Subject: Special
Received: 2021/12/28 | Accepted: 2022/08/15 | Published: 2022/09/21

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Archives of Occupational Health

Designed & Developed by : Yektaweb