<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Archives of Occupational Health</title>
<title_fa>آرشیو بهداشت حرفه ای</title_fa>
<short_title>AOH</short_title>
<subject>Basic Sciences</subject>
<web_url>http://aoh.ssu.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2588-3070</journal_id_issn>
<journal_id_issn_online>2588-3690</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1400</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>6</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa>Validity of estimating the 3 KHz audiometric threshold by averaging the thresholds on 2 and 4 KHz in cases of Noise induced Hearing Loss. Pure Tone Audiometry and electrophysiological data.</title_fa>
	<title>Validity of Estimating the 3 kHz Audiometric Threshold by Averaging the Thresholds at 2 and 4 kHz in Cases of Noise-Induced Hearing Loss</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa></abstract_fa>
	<abstract>&lt;strong&gt;Background:&lt;/strong&gt;&amp;nbsp;Hearing thresholds at 3000 Hz are generally not measured in routine clinical audiometry. However, for purposes other than clinical diagnosis, the threshold at 3 kHz has many applications, in epidemiological studies in the field of occupational health and medicine, as well as in (medicolegal) quantification of physical impairment due to hearing loss, particularly noise-induced hearing loss (NIHL). The present study addressed the validity of estimating, in the case of NIHL, the 3 kHz-audiometric thresholds by averaging the thresholds at 2 and 4 kHz.&amp;nbsp;&lt;strong&gt;Methods:&lt;/strong&gt;&amp;nbsp;All 200 investigated subjects (400 ears) had a well-documented noise exposure, moderate to severe NIHL, and underwent, as they were claiming for compensation, a detailed medicolegal audiological investigation, including beside pure tone audiometry, electrophysiological objective frequency-specific threshold definition using cortical evoked response audiometry (CERA) and auditory steady-state response (ASSR). &lt;strong&gt;Results:&lt;/strong&gt; The study results showed a good correlation between the 2-4 kHz interpolation and the actual 3 kHz threshold; the error may be around 2 dB on average. However, in individual cases, the results demonstrated that the error due to interpolation exceeds 5 dB HL in about one-quarter of the cases. This error is predictable; the larger the 2- 4 KHz difference (which reflects the steepness of the left slope of the audiometric notch), the larger the error (on either side) made by interpolating. &lt;strong&gt;Conclusion:&lt;/strong&gt; For epidemiological studies with large amounts of data, the interpolated threshold (average of 2 and 4 KHz) may be considered as a valid estimate of the true value of the 3 KHz threshold. More caution is required in individual cases: the error due to interpolation exceeds 5 dB HL in about one-quarter of the cases, but this error is predictable.&lt;br&gt;
&amp;nbsp;</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Hearing Loss, Noise-induced, Audiometry, Evoked Response, Auditory Threshold</keyword>
	<start_page>1171</start_page>
	<end_page>1182</end_page>
	<web_url>http://aoh.ssu.ac.ir/browse.php?a_code=A-10-292-1&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>DeJonckere</first_name>
	<middle_name></middle_name>
	<last_name>Philippe Henri</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ph.dejonckere@outlook.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Federal Agency for Occupational Risks, B-1210 Brussels, Belgium</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Lebacq</first_name>
	<middle_name></middle_name>
	<last_name>Jean</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>jean.lebacq@uclouvain.be</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Institute of Neurosciences, University of Louvain, B-1200 Brussels, Belgium</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
