<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Archives of Occupational Health</title>
<title_fa>آرشیو بهداشت حرفه ای</title_fa>
<short_title>AOH</short_title>
<subject>Basic Sciences</subject>
<web_url>http://aoh.ssu.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2588-3070</journal_id_issn>
<journal_id_issn_online>2588-3690</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>7</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی رابطه صدای اورژانس با مزاحمت ناشی از آن در بیمارستان های دانشگاه علوم پزشکی تهران</title_fa>
	<title>The Relationship between the Environmental Noise Intensity, Feeling and Annoyance with the Shiftwork in the Emergency Department</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>گزارش مورد</content_type_fa>
	<content_type>case report</content_type>
	<abstract_fa>مقدمه: آلودگی صوتی یکی از عوامل خطرناک در محیط زیست انسان است. اورژانس بیمارستان ها یکی از مهم ترین و پرترددترین بخش های بیمارستان ها می باشد. وجود آلودگی صوتی در این قسمت به دلیل بیماران اورژانسی و اقدامات درمانی خاص، سلامت پرسنل و رضایت مراجعین را تحت تاثیر قرار داده و می تواند منجر به کاهش بهره وری در حوادث کار شود.&lt;br&gt;
&amp;nbsp; مواد و روش ها: این مطالعه مقطعی (توصیفی- تحلیلی) به منظور تعیین میزان صدای محیط کار و مزاحمت ناشی از آن در اورژانس بیمارستان های دانشگاه علوم پزشکی تهران در سال 1401 انجام شد. صدای TES-1351B. سطح سنج برای اندازه گیری سطح فشار صوت استفاده شد. و ایستگاه های اندازه گیری بر اساس استاندارد ISO 9612 تعیین شدند. برای تعیین مشخصات دموگرافیک از پرسشنامه عمومی و برای تعیین میزان مزاحمت صدا از پرسشنامه خود اعلامی استفاده شد. داده های جمع آوری شده با استفاده از نرم افزار آماری SPSS نسخه 22 مورد تجزیه و تحلیل قرار گرفت.&lt;br&gt;
&amp;nbsp; یافته&#8204;ها: میانگین فشار صوت کلی در بخش اورژانس بیمارستان&#8204;های مورد مطالعه 70/7&amp;plusmn;940/67 دسی&#8204;بل بود. نتایج تحقیق تفاوت معنی داری را بین سطح فشار صوت در شیفت صبح و عصر نشان داد (001/0=p-value). بالاترین میانگین تراز فشار صوت مربوط به شیفت عصر با میانگین 4.35&amp;plusmn;72.382 دسی بل بود. بین شدت صوت درک شده جمعیت مورد مطالعه در بیمارستان&#8204;های امام خمینی و سینا تفاوت معنی&#8204;داری وجود داشت (031/0=p-value) و همچنین بین مزاحمت صوتی در بیمارستان&#8204;های امام خمینی و سینا تفاوت معنی&#8204;داری وجود داشت (008/0=p-value). .&lt;br&gt;
نتیجه&#8204;گیری: میانگین سطح فشار صوت در هر سه بیمارستان دانشگاهی مورد بررسی بالاتر از حد مجاز WHO (dB40-30) بود. افزایش شدت صدا در بیمارستان&#8204;های امام خمینی (ره) و شریعتی بیش از صدا مزاحمت ایجاد می&#8204;کند که نیازمند برنامه&#8204;ریزی و اتخاذ تدابیر اداری و فنی-مهندسی برای کاهش آلودگی صوتی تا حد مجاز استاندارد است.</abstract_fa>
	<abstract>&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span calibri=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span 47=&quot;&quot; cn=&quot;&quot; lt=&quot;&quot; std=&quot;&quot; style=&quot;font-family:&quot; univers=&quot;&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;Background: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span adobe=&quot;&quot; garamond=&quot;&quot; pro=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;Noise pollution is a serious issue in hospitals, especially in emergency departments where high noise levels from emergency patients and treatments can negatively affect medical personnel and patients. This study aimed to measure noise levels during day and night shifts in three major hospitals affiliated with Tehran University of Medical Sciences (Imam Khomeini, Shariati, and Sina hospitals) and investigate the level of annoyance experienced by medical staff. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span 47=&quot;&quot; cn=&quot;&quot; lt=&quot;&quot; std=&quot;&quot; style=&quot;font-family:&quot; univers=&quot;&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;Methods:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span adobe=&quot;&quot; garamond=&quot;&quot; pro=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt; In this cross-sectional studyTES-1351B sound level meter was used to measure sound pressure levels and the measurement stations were determined according to ISO 9612 standard. A general questionnaire was used to determine demographic characteristics. Also, by a valid self-reporting questionnaire, the feeling about environmental noise intensity and noise annoyance was measured. Statistical analysis was done by SPSS software using ANOVA and t-test. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span 47=&quot;&quot; cn=&quot;&quot; lt=&quot;&quot; std=&quot;&quot; style=&quot;font-family:&quot; univers=&quot;&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;Results:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span adobe=&quot;&quot; garamond=&quot;&quot; pro=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt; The average sound pressure level in the emergency departments of the studied hospitals was 67.940&amp;plusmn;7.70 dB. Significant differences were found between morning and evening shift noise levels. (p-value=0.001). The highest average sound pressure level occurred during the evening shift with an average of 72.382&amp;plusmn;4.35 db. Also, there was a significant difference between the feeling about environmental noise intensity and noise annoyance in Imam Khomeini and Sinai hospitals respectively, (p-value=0.037) (p-value=0.011). &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span 47=&quot;&quot; cn=&quot;&quot; lt=&quot;&quot; std=&quot;&quot; style=&quot;font-family:&quot; univers=&quot;&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;Conclusion:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span adobe=&quot;&quot; garamond=&quot;&quot; pro=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt; The study concludes that noise pollution in the emergency departments of these hospitals needs attention. Implementing administrative and technical-engineering measures to reduce noise pollution is essential to enhance the well-being of medical staff and patients and ensure a more satisfactory healthcare environment.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Noise, Annoyance, Emergency department, Shift Work Schedule</keyword>
	<start_page>1377</start_page>
	<end_page>1384</end_page>
	<web_url>http://aoh.ssu.ac.ir/browse.php?a_code=A-10-349-1&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Farhanaz</first_name>
	<middle_name></middle_name>
	<last_name>Khajeh Nasiri</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>1Department of Social Medicine, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>zahrasadat</first_name>
	<middle_name></middle_name>
	<last_name>mousavifard</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mossavizahra@modares.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Occupational Health Engineering, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
