Volume 5, Issue 2 (April 2021)                   AOH 2021, 5(2): 980-987 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mehri A, Sajedifar J, Abbasi M, Tajbakhsh M A, Mohammadian F, Salehian T et al . The Evaluation of the Lighting at the Entrance of Very Long Tunnels. AOH 2021; 5 (2) :980-987
URL: http://aoh.ssu.ac.ir/article-1-242-en.html
1- Department of occupational hygiene, School of Public Health, Hamadan university of medical sciences, Hamadan, Iran
2- Department of Occupational Health Engineering, School of Public Health, Neyshabur University of Medical Sciences, Neyshabur, Iran,Department of Occupational Health Engineering, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
3- Social Determinates of Health Research Center, Saveh University of Medical Sciences, Saveh, Iran
4- Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
5- 6Assistant Professor, Department of Occupational Health and Safety Engineering, Environmental Health Research Center, Research Institute for Health Development, Kurdistan University of Medical Sciences, Sanandaj, Iran
6- Department of Nursing & Midwifery,iranshahr University of Medical sciences,iranshahr,iran
7- Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran , szakerian@gmail.com
Abstract:   (1006 Views)
Background: One of the major topics related to the very long tunnels is dark hole effect. This is a common phenomenon caused by the sunlight reflected from the surroundings of the tunnel to the eyes of drivers and the lack of sufficient light at the tunnels' entrance, which decreases the contrast of barriers inside the tunnel and also makes it difficult to see potential obstacles at the entrance. The result is an increased risk of traffic accidents in these tunnels. Therefore, the aim of this research is to subjectively assessment the safe rate of lighting in one of the very long tunnels located in the province of Ilam. Methods: To subject evaluation the safe rate of lighting at the tunnel entrances, two parameters of the average luminance of tunnel entrance and equivalent luminance are required. In this study, Luminancemeter device model S3 was used to measure the average luminance of tunnel entrance. Then, to calculate the equivalent luminance, a YASHICA108 camera with a 35 mm lens was photographed at a distance between the tunnel entrance and a safe stopping point, and then the Holliday polar diagram was used to calculate equivalent luminance (accordance with the standard CIE88-2004). Results: In this study, the average luminance at tunnel's entrance was equal to 17 , the luminance was equal to 127.5  Using the ADRENAL equation, the quality of lightening at the tunnel entrance was less than 1. Conclusion: Comparison of the results obtained from the healthy and safety rate of lighting levels at the tunnel's entrance with the De Boer mental scale indicated that a dark hole effect occurs at the entrance of the tunnel under investigation and the light sources installed at the entrance of this tunnel did not have the sufficient ability to inhibit the dark hole effect.
Full-Text [PDF 3147 kb]   (252 Downloads)    
Type of Study: Research | Subject: Special
Received: 2020/10/22 | Accepted: 2021/04/9 | Published: 2021/04/9

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Archives of Occupational Health

Designed & Developed by : Yektaweb